| Module | Sequel::SQLite::DatabaseMethods |
| In: |
lib/sequel/adapters/shared/sqlite.rb
|
No matter how you connect to SQLite, the following Database options can be used to set PRAGMAs on connections in a thread-safe manner: :auto_vacuum, :foreign_keys, :synchronous, and :temp_store.
| AUTO_VACUUM | = | [:none, :full, :incremental].freeze |
| PRIMARY_KEY_INDEX_RE | = | /\Asqlite_autoindex_/.freeze |
| SYNCHRONOUS | = | [:off, :normal, :full].freeze |
| TABLES_FILTER | = | "type = 'table' AND NOT name = 'sqlite_sequence'".freeze |
| TEMP_STORE | = | [:default, :file, :memory].freeze |
| VIEWS_FILTER | = | "type = 'view'".freeze |
| use_timestamp_timezones | [W] | Override the default setting for whether to use timezones in timestamps. For backwards compatibility, it is set to true by default. Anyone wanting to use SQLite‘s datetime functions should set it to false using this method. It‘s possible that the default will change in a future version, so anyone relying on timezones in timestamps should set this to true. |
A symbol signifying the value of the auto_vacuum PRAGMA.
# File lib/sequel/adapters/shared/sqlite.rb, line 15
15: def auto_vacuum
16: AUTO_VACUUM[pragma_get(:auto_vacuum).to_i]
17: end
Set the auto_vacuum PRAGMA using the given symbol (:none, :full, or :incremental). See pragma_set. Consider using the :auto_vacuum Database option instead.
# File lib/sequel/adapters/shared/sqlite.rb, line 22
22: def auto_vacuum=(value)
23: value = AUTO_VACUUM.index(value) || (raise Error, "Invalid value for auto_vacuum option. Please specify one of :none, :full, :incremental.")
24: pragma_set(:auto_vacuum, value)
25: end
Set the case_sensitive_like PRAGMA using the given boolean value, if using SQLite 3.2.3+. If not using 3.2.3+, no error is raised. See pragma_set. Consider using the :case_sensitive_like Database option instead.
# File lib/sequel/adapters/shared/sqlite.rb, line 36
36: def case_sensitive_like=(value)
37: pragma_set(:case_sensitive_like, !!value ? 'on' : 'off') if sqlite_version >= 30203
38: end
Boolean signifying the value of the foreign_keys PRAGMA, or nil if not using SQLite 3.6.19+.
# File lib/sequel/adapters/shared/sqlite.rb, line 47
47: def foreign_keys
48: pragma_get(:foreign_keys).to_i == 1 if sqlite_version >= 30619
49: end
Set the foreign_keys PRAGMA using the given boolean value, if using SQLite 3.6.19+. If not using 3.6.19+, no error is raised. See pragma_set. Consider using the :foreign_keys Database option instead.
# File lib/sequel/adapters/shared/sqlite.rb, line 54
54: def foreign_keys=(value)
55: pragma_set(:foreign_keys, !!value ? 'on' : 'off') if sqlite_version >= 30619
56: end
Use the index_list and index_info PRAGMAs to determine the indexes on the table.
# File lib/sequel/adapters/shared/sqlite.rb, line 59
59: def indexes(table, opts={})
60: m = output_identifier_meth
61: im = input_identifier_meth
62: indexes = {}
63: begin
64: metadata_dataset.with_sql("PRAGMA index_list(?)", im.call(table)).each do |r|
65: next if r[:name] =~ PRIMARY_KEY_INDEX_RE
66: indexes[m.call(r[:name])] = {:unique=>r[:unique].to_i==1}
67: end
68: rescue Sequel::DatabaseError
69: nil
70: else
71: indexes.each do |k, v|
72: v[:columns] = metadata_dataset.with_sql("PRAGMA index_info(?)", im.call(k)).map(:name).map{|x| m.call(x)}
73: end
74: end
75: indexes
76: end
Get the value of the given PRAGMA.
# File lib/sequel/adapters/shared/sqlite.rb, line 79
79: def pragma_get(name)
80: self["PRAGMA #{name}"].single_value
81: end
Set the value of the given PRAGMA to value.
This method is not thread safe, and will not work correctly if there are multiple connections in the Database‘s connection pool. PRAGMA modifications should be done when the connection is created, using an option provided when creating the Database object.
# File lib/sequel/adapters/shared/sqlite.rb, line 89
89: def pragma_set(name, value)
90: execute_ddl("PRAGMA #{name} = #{value}")
91: end
The version of the server as an integer, where 3.6.19 = 30619. If the server version can‘t be determined, 0 is used.
# File lib/sequel/adapters/shared/sqlite.rb, line 95
95: def sqlite_version
96: return @sqlite_version if defined?(@sqlite_version)
97: @sqlite_version = begin
98: v = get{sqlite_version{}}
99: [10000, 100, 1].zip(v.split('.')).inject(0){|a, m| a + m[0] * Integer(m[1])}
100: rescue
101: 0
102: end
103: end
A symbol signifying the value of the synchronous PRAGMA.
# File lib/sequel/adapters/shared/sqlite.rb, line 129
129: def synchronous
130: SYNCHRONOUS[pragma_get(:synchronous).to_i]
131: end
Set the synchronous PRAGMA using the given symbol (:off, :normal, or :full). See pragma_set. Consider using the :synchronous Database option instead.
# File lib/sequel/adapters/shared/sqlite.rb, line 135
135: def synchronous=(value)
136: value = SYNCHRONOUS.index(value) || (raise Error, "Invalid value for synchronous option. Please specify one of :off, :normal, :full.")
137: pragma_set(:synchronous, value)
138: end
A symbol signifying the value of the temp_store PRAGMA.
# File lib/sequel/adapters/shared/sqlite.rb, line 149
149: def temp_store
150: TEMP_STORE[pragma_get(:temp_store).to_i]
151: end
Set the temp_store PRAGMA using the given symbol (:default, :file, or :memory). See pragma_set. Consider using the :temp_store Database option instead.
# File lib/sequel/adapters/shared/sqlite.rb, line 155
155: def temp_store=(value)
156: value = TEMP_STORE.index(value) || (raise Error, "Invalid value for temp_store option. Please specify one of :default, :file, :memory.")
157: pragma_set(:temp_store, value)
158: end
SQLite supports timezones in timestamps, since it just stores them as strings, but it breaks the usage of SQLite‘s datetime functions.
# File lib/sequel/adapters/shared/sqlite.rb, line 124
124: def use_timestamp_timezones?
125: defined?(@use_timestamp_timezones) ? @use_timestamp_timezones : (@use_timestamp_timezones = true)
126: end